1) track between resistance of not less than 10 ohms. To this end the rail should be insulated handle. Tu Liqing rail bottom, rubber insulation board pad 5mm, railon both sides of filling sand asphalt.
2) 36V track the actual voltage should be not greater than 42V. The lines are notsegment the start should be not less than 30V, otherwise must be compensatedline.
3) on both sides of the maximum operating distance of the step-down transformer can refer to the following table, unilateral maximum range of values listed in the table of semi. When the distance is longer, the number may increase the step-down transformer, multi point power supply, transformer should be connected to the same power supply transformer phase, the number of not more than 3.
4) such as the seam track, rail joints is due 5mm * 45 degree chamfer, lest andfriction power block under the edge collision. Recommend the use of welding of rail welding joint after welding, grinding.
5) KPD series is a 36V low voltage rail to rail power supply electric flat car, the sliding contact line power supply. Track construction requirements higher, should ensure that the rail insulation. The prohibition of metal parts at the same time to touch the two track.